Airway Management

Anaesthesia Breathing Systems

Anaesthesia Components

Critical Care

Neonatal Breathing Systems

Breathing Filters

Oxygen & Aerosol Therapy

Resuscitation

Suction

Urology & Continence Care

Colostomy

Enema Tips

Humidified Ventilator Systems

 

Principles of Humidity
Under normal circumstances inspired gas is warmed, filtered and moistened during its passage through the upper airways, a process which is bypassed by endotracheal intubation and tracheostomy exposing the lungs and airways to dry cold gas giving rise to a number of adverse effects including: An increase in Mucus Viscosity, Depressed ciliary activity and Obstruction of the airways by tenacious secretions. Artificial humidification of inspired gases is therefore essential when the upper respiratory tract is bypassed.


Manual and Auto Fill Chambers share the following features:

Compatible with all circuits
22mm connectors allow compatibility with the wide range
of circuits available.

Clear construction
Clear construction of the humidification chamber allows constant monitoring of the water.

Heat Transfer
Effective Heat Transfer From Aluminium Base.
Durable
The durable construction means that the chamber is impact resistant.

Gas Flow Diverters
The diverters ensure the patient receives a higher level of humidified air, by maximizing the flow as it passes through
the chamber.

038-31-750.gif

Manual Fill Chamber

038-31-740.gif

Auto Fill Chamber

Product CodeDescriptionPack SizeImage
038-31-750 Manual Fill Humidification Chamber - 220ml Capacity 20
038-31-740 Auto Fill Humidification Chamber - 210ml Capacity 20
038-31-755 Ventilator Breathing System (1.6m)
with Y piece, monitoring ports, water trap and manual fill humidification chamber.
10
038-31-760 Ventilator Breathing System (1.6m)
with Y piece, monitoring ports, 2 water traps and manual fill humidification chamber
10
038-31-756 Ventilator Breathing System (1.6m)
with Y piece, monitoring ports, water trap and auto fill humidification chamber.
10
038-31-761 Ventilator Breathing System (1.6m)
with Y piece, monitoring ports, 2 water traps and auto fill humidification chamber
10
038-31-765 Ventilator Breathing System (1.6m) Heated Wire
with Y piece, monitoring ports, water trap and manual fill humidification chamber.
10
038-32-765 Paediatric Ventilator Breathing System (1.6m) Heated Wire
with Y piece, monitoring ports, 2 water traps and manual fill humidification chamber
10
038-31-767 Ventilator Breathing System (1.6m) Heated Wire
with Y piece, monitoring ports, water trap and auto fill humidification chamber.
10
038-32-767 Paediatric Ventilator Breathing System (1.6m) Heated Wire
with Y piece, monitoring ports, 2 water traps and auto fill humidification chamber
10
038-31-745 Dual Heated Wire Breathing System (1.6m)
with Y piece, monitoring ports and manual fill humidification chamber.
10
038-32-747 Paediatric Dual Heated Wire Breathing System (1.6m)
with Y piece, monitoring ports and auto fill humidification chamber.
10
038-31-766 Ventilator Breathing System (1.6m) Heated Wire
with Y piece, monitoring ports, water trap and manual fill humidification chamber.
10
038-32-766 Paediatric Ventilator Breathing System (1.6m) Heated Wire
with Y piece, monitoring ports, 2 water traps and manual fill humidification chamber
10
038-31-768 Ventilator Breathing System (1.6m) Heated Wire
with Y piece, monitoring ports, water trap and auto fill humidification chamber.
10
038-32-768 Paediatric Ventilator Breathing System (1.6m) Heated Wire
with Y piece, monitoring ports, 2 water traps and auto fill humidification chamber
10
038-31-746 Dual Heated Wire Breathing System (1.6m)
with Y piece, monitoring ports and manual fill humidification chamber.
10
038-32-748 Paediatric Dual Heated Wire Breathing System (1.6m)
with Y piece, monitoring ports and auto fill humidification chamber.
10