Airway Management

Anaesthesia Breathing Systems

Anaesthesia Components

Critical Care

Neonatal Breathing Systems

Breathing Filters

Oxygen & Aerosol Therapy

Resuscitation

Suction

Urology & Continence Care

Colostomy

Enema Tips

Neonatal Breathing Systems

 

The range of neonatal circuits for use in the NICU provides choice of active or passive humidification.

lowdeadspace.gif Low Dead Space Neonatal Y-Piece
Very low dead space and rounded design reduces the risk of rebreathing (5.5 cubic cm/ml ). The self sealing suction port allows for suctioning the patient without affecting the delivery of fresh gases.
pressureline.gif Pressure Line
Fitted to the centre of the Y-Piece, it will measure the pressure in the circuit providing the most accurate information.
selfseal.gif Self Seal Water Trap
The self sealing water trap incorporates a non-return valve that protects against the accidental flow of any liquids from the water trap into the circuit.
heatedwire.gif Heated Wire Limb
The inspiratory heated wire limb maintains the temperature and humidified fresh gases to the point of delivery at the patient end whilst reducing condensation in the circuit. This allows for saturated fresh gases to be delivered to the patient at the required temperature. Dual heated wire option is available to reduce condensation in the expiratory limb.
10mmcorrugated.gif 10mm Corrugated Tubing
The 10mm corrugated tubing with shallow corrugations reduces the resistance to flow while maintaining a low compliance and allowing for fast delivery of fresh gases to the patient. The lightweight of the tubing minimizes the drag on the patient. The structure of the 10mm corrugated tube allows the use of the circuit with oscillating ventilators.
monitoringport.gif Monitoring Port
The detachable monitoring port can be moved close to the y-piece or moved further away when the circuit is used with incubated patients.
15mmconnectiors.gif 15mm Connectors
The neonatal range of circuits have standard fitting 15mm connectors.
choice.gif

Choice of heated wire connector
There are two different heated wire connectors to fit the specific humidifiers available.

 

Flying Lead Connection Clover Leaf Connection

clover-flying-lead.gif

Product CodeDescriptionPack SizeImage
038-03-315 Neonatal Cold Humidification Breathing System
with temperature port and pressure line. 10mm 1.8m corrugated tube with neonatal y-piece, pressure line, water trap, 4 flexible 15M/F connectors and 0.5m spare limb
20
038-03-315C As above with auto-fill humidification chamber 20
038-03-310 Neonatal Universal Heated Wire Breathing System with detachable inspiratory and expiratory temperature ports and pressure line (for use with incubators) 10mm 1.8m corrugated tube with neonatal y-piece, pressure line, water trap, 4 flexible connectors and 0.5m spare limb with flying lead connection 20
038-03-310C As above with auto-fill humidification chamber 20
038-03-311 Neonatal Universal Heated Wire Breathing System with detachable inspiratory and expiratory temperature ports and pressure line (for use with incubators) 10mm 1.8m corrugated tube with neonatal y-piece, pressure line, water trap, 4 flexible connectors and 0.5m spare limb with clover leaf connection 20
038-03-311C As above with auto-fill humidification chamber 20
038-03-340 Neonatal Heated Wire Breathing System with inspiratory temperature port and pressure line. 10mm corrugated tube with neonatal y-piece, pressure line, water trap, 2 flexible 15M/F connectors and 2 x 0.5m spare limbs with clover leaf connector 20
038-03-340C As above with auto-fill humidification chamber 20
038-03-341 Neonatal Heated Wire Breathing System with inspiratory temperature port and pressure line. 10mm corrugated tube with neonatal y-piece, pressure line, water trap, 2 flexible 15M/F connectors and 2 x 0.5m spare limbs with flying lead connector 20
038-03-341C As above with auto-fill humidification chamber 20
038-03-345 Neonatal Dual Heated Wire Breathing System with inspiratory and expiratory temperature ports, and pressure line with flying lead connector 20
038-03-345C As above with auto-fill humidification chamber 20
038-03-346 Neonatal Dual Heated Wire Breathing System with inspiratory and expiratory temperature ports, and pressure line with clover leaf connector 20
038-03-346C As above with auto-fill humidification chamber 20
038-03-100 Neonatal Nitric Oxide Adapter Kit 20
038-31-750 Manual Fill Humidification Chamber - 220ml Capacity 20
038-31-740 Auto Fill Humidification Chamber - 210ml Capacity 20