Flexicare have designed a range of neonatal circuits for use in the NICU providing choice of active or passive humidification.

baby-600.jpg 

Y-piece.jpg Low Dead Space Neonatal Y-Piece
Very low dead space and rounded design reduces the risk of Rebreathing. The self sealing suction port allows for suctioning the patient without affecting the delivery of fresh gases to the patient.
Monitoring-Line.jpg 10mm Corrugated Tubing
The 10mm corrugated tubing with shallow corrugations reduces the resistance to flow while maintaining a low compliance and allows for fast delivery of fresh gases to the patient. The lightweight of the tubing minimizes the drag on the patient.
Monitoring-Line-2.jpg Pressure Line
Fitted to the centre of the Y-Piece will measure the pressure in the circuit providing the most accurate information.
monitoring-port.jpg Monitoring Port
The detachable monitoring port can be moved close to the y-piece or moved further away when the circuit is used with incubated patients.
Water-Trap.jpg Self Seal Water Trap
The self sealing water trap incorporates a non-return valve that protects against the accidental flow of any liquids from the water trap into the circuit.
Connectors.jpg 15mm Connectors
The neonatal range of circuits have standard fitting 15mm connectors.
Monitoring-port-2.jpg Heated Wire Limb
The inspiratory heated wire limb maintains the temperature and humidified fresh gases to the point of delivery at the patient end and reduces condensation in the circuit. This allows for saturated fresh gases to be delivered to the patient at the required temperature.
Heated-wire-connector.jpg Choice of heated wire connector
Flexicare offers two different heated wire connectors to fit the specific heaters available.
Flying Lead Connector Clover Leaf Connector
Flying-Lead.jpg Clover-Leaf.jpg

Product CodeDescriptionPack SizeImage
038-03-315U Neonatal Cold Humidification Breathing System
with temperature port and pressure line. 10mm 1.8m corrugated tube with neonatal y-piece, pressure line, water trap, 4 flexible 15M/F connectors and 0.5m spare limb with flying lead connector.
20
038-03-315CU As above with auto-fill humidification chamber 20
038-03-310U Neonatal Universal Heated Wire Breathing System with detachable inspiratory and expiratory temperature ports and pressure line (for use with incubators) 20
038-03-310CU As above with auto-fill humidification chamber 20
038-03-311U Neonatal Universal Heated Wire Breathing System with detachable inspiratory and expiratory temperature ports and pressure line (for use with incubators). 10mm 1.8m corrugated tube with neonatal y-piece, pressure line, watre trap, 4 flexible connectors and 0.5m spare limb with clover leaf connector 20
038-03-311CU As above with auto-fill humidification chamber 20
038-03-340U Neonatal Heated Wire Breathing System with inspiratory temperature port and pressure line. 10mm corrugated tube with neonatal y-piece, pressure line, water trap, 2 flexible 15M/F connectors and 2 x 0.5m spare limbs with clover leaf connector 20
038-03-340CU As above with auto-fill humidification 20
038-03-341U Neonatal Heated Wire Breathing System with inspiratory temperature port and pressure line. 10mm corrugated tube with neonatal y-piece, pressure line, water trap, 2 flexible 15M/F connectors and 2 x 0.5m spare limbs with flying lead connector 20
038-03-341CU As above with auto-fill humidification chamber 20
038-03-345U Neonatal Dual Heated Wire Breathing System with inspiratory and expiratory tempeRature ports, and pressure line with flying lead connector 20
038-03-345CU As above with auto-fill humidification chamber 20
038-03-346U Neonatal Dual Heated Wire Breathing System with inspiratory and expiratory temperature ports, and pressure line with clover leaf connector 20
038-03-346CU As above with auto-fill humidification chamber 20